Brightfield S1200T Portable Transport Ventilator
Reviews (0)The Brightfield S1200T is a compact, turbine-driven transport ventilator designed for respiratory support during emergency care, ambulance transport, and patient transfers within and between healthcare facilities. Weighing just 6.5 kg, it combines 13 ventilation modes, adaptive minute ventilation (AMV), high-flow oxygen therapy, and advanced respiratory monitoring. Optional features include a tidal volume range starting at 2 mL for neonatal patients and a dedicated CPRV mode for cardiopulmonary resuscitation.
Product Speciality
About product
Reliable Respiratory Support Wherever Care Is Needed
The Brightfield S1200T is a portable mechanical ventilator developed for clinical situations where respiratory support must continue beyond a conventional intensive care setting. It is suitable for ambulance services, emergency departments, operating rooms, intensive care units, military medical teams, and field stabilization facilities.
Its integrated turbine generates the airflow required for ventilation without relying on a centralized compressed-air supply. Combined with a portable oxygen source and battery power, this makes the S1200T a practical solution for transporting patients who require continuous respiratory assistance.
With a weight of approximately 6.5 kg, a rugged IP34-rated enclosure, and an 8.4-inch color display, the ventilator combines portability with access to essential respiratory parameters. The system also incorporates automatic leak compensation to help maintain ventilation performance when leakage occurs in the patient circuit or around the mask.
Ventilation Modes and Clinical Capabilities
The Brightfield S1200T supports both invasive and non-invasive respiratory care, with ventilation settings that can be adjusted according to the patient’s condition, breathing activity, and treatment requirements.
- 13 ventilation modes: VCV, V-SIMV, PRVC, P-A/C, CPAP/PSV, PRVC-SIMV, P-SIMV, NIV-ST, DuoPAP, APRV, AMV, NIV-S, and Apnea.
- Adaptive Minute Ventilation (AMV): Automatically calculates ventilation settings based on the patient’s ideal body weight and adjusts respiratory support in response to changes in spontaneous breathing.
- Neonatal ventilation option: An extended tidal volume range starting at 2 mL supports ventilation requirements for newborns and small pediatric patients when the appropriate configuration is installed.
- Weaning Assistance Tool (SBT): A structured spontaneous breathing trial helps clinicians assess a patient’s readiness for withdrawal from mechanical ventilation.
- CPRV mode (optional): A dedicated ventilation function supports synchronized respiratory assistance during cardiopulmonary resuscitation.
- Respiratory mechanics assessment: Dynamic Lung Display and the P-V Tool provide additional information on lung mechanics, respiratory system compliance, and airway resistance.
- High-flow oxygen therapy: Expands the available respiratory support options beyond conventional mechanical ventilation.
Respiratory Monitoring and Safety
The S1200T integrates respiratory monitoring with visual and audible alarm notifications. Clinicians can observe airway pressure, tidal volume, respiratory rate, oxygen saturation (SpO2), and end-tidal carbon dioxide (EtCO2), depending on the installed monitoring configuration.
The alarm system alerts medical personnel when monitored values exceed the configured limits or when problems such as circuit disconnection, obstruction, or abnormal airway pressure occur. An alarm silence control is available for temporary audible alarm suppression.
Automatic leak compensation helps maintain the selected ventilation parameters during non-invasive ventilation and in situations involving circuit leakage.
Portable Design and Extended Battery Operation
Designed for transport medicine, the Brightfield S1200T features a compact housing, an integrated turbine, and a convenient carrying arrangement. The IP34 enclosure provides protection against limited ingress of solid particles and water splashes, making the unit suitable for demanding clinical transport environments.
One battery provides up to 4 hours of operation, while the optional dual-battery configuration extends the operating time to up to 8 hours. This supports patient transfers and emergency interventions when external electrical power is unavailable.
Equipment Configuration and Accessories
The S1200T can be supplied with a set of accessories for transport ventilation and patient monitoring. The configuration may include:
- Main ventilator unit: Built-in turbine, display, lithium-ion batteries, connection cables, and transport bag.
- Breathing circuits and masks: Reusable patient circuits and masks for adult and pediatric use, oxygen tubing, and a test lung for equipment checks.
- Monitoring modules: SpO2 and EtCO2 modules for oxygen saturation monitoring and end-tidal carbon dioxide measurement.
- Oxygen supply accessories: A 2-liter oxygen cylinder, oxygen supply hose, and tubing compatible with different patient groups.
The exact scope of delivery, available options, and accessory selection should be confirmed when ordering.
Brightfield S1200T for Emergency and Critical Care
From ambulance ventilation to intrahospital transfers and field emergency medicine, the Brightfield S1200T offers a broad selection of respiratory support modes in a portable system. Its integrated turbine, adaptive ventilation functions, patient monitoring capabilities, and battery-powered operation make it suitable for clinical teams working in mobile and critical care environments.
Contact us to discuss the Brightfield S1200T transport ventilator, available configurations, technical specifications, and purchasing options.
About product
Interested in this solution?
Get pricing, detailed technical specifications, product availability, and expert guidance from our specialist team. We will help you choose the right solution for your clinic, hospital, or medical facility.