Brightfield Introduces: A New Dual-Endoscope Reprocessor A2 for 2026
November 4, 2026
Brightfield introduces the new ScopeJET A2 Automatic Endoscope Reprocessor for 2026, designed to wash and disinfect two flexible endoscopes in a single cycle. Featuring a 14-liter processing bath, automatic leak-tightness testing, eight configurable programs and integrated cycle documentation, the new model expands Brightfield’s endoscope reprocessing range beyond the previous single-endoscope system.
Introducing ScopeJET A2: Two Endoscopes in One Processing Cycle
In 2026, Brightfield introduces the new ScopeJET A2 Automatic Endoscope Reprocessor, designed to wash and perform high-level disinfection of two flexible endoscopes simultaneously. Compared with the previous single-endoscope SterixX reprocessor, the new model doubles the number of endoscopes processed per cycle, helping endoscopy departments organize reprocessing more efficiently.
Developed by Brightfield Ukraine, ScopeJET A2 expands the company’s endoscope reprocessing equipment range with a 14-liter processing bath, automated washing and disinfection, programmable processing profiles and integrated cycle documentation.
The new model is designed for hospitals, endoscopy departments and medical facilities that need to process multiple flexible endoscopes within a standardized workflow.
Double the Endoscope Capacity per Cycle
The most significant advancement of ScopeJET A2 is its capacity to process two flexible endoscopes during a single automated cycle.
The previous SterixX reprocessor was designed to accommodate one endoscope in a 7-liter bath. ScopeJET A2 introduces a 14-liter bath configured for two endoscopes, allowing both instruments to undergo washing and high-level disinfection within the same processing cycle.
This configuration provides an important operational advantage for endoscopy departments with multiple instruments requiring reprocessing between examinations.
By accommodating two endoscopes simultaneously, ScopeJET A2 can reduce the number of separate processing cycles required for a given set of instruments, although total processing time depends on the selected program and operating conditions.
Expanded Capacity for Processing Fluids
The new two-endoscope configuration is accompanied by an increased disinfectant tank capacity.
ScopeJET A2 features a 15-liter disinfectant tank, compared with 8 liters in the previous single-endoscope model.
The detergent and alcohol tanks each have a capacity of 1 liter. Automatic dosing supplies processing fluids according to the selected program, reducing the need for manual handling during routine washing and disinfection.
The expanded bath and disinfectant tank capacities are designed to accommodate the requirements of the new dual-endoscope processing system.
Eight Configurable Processing Profiles
ScopeJET A2 incorporates an integrated computer that controls the programmed sequence of washing, disinfection and rinsing.
The system provides up to eight individually configurable processing profiles, allowing users to select appropriate settings for different endoscope reprocessing requirements.
Washing and disinfection times can be adjusted according to the selected procedure. A 4-inch touchscreen provides access to the main operating controls and processing programs.
This configuration helps medical personnel organize recurring reprocessing tasks using predefined settings.
Automatic Leak-Tightness Testing and Double Rinsing
ScopeJET A2 retains important functions for controlled endoscope reprocessing.
The system performs automatic leak-tightness testing during the processing cycle, helping personnel detect potential loss of endoscope integrity.
The processing chamber features a sealed lid with a perimeter gasket, while the double-rinse function provides an additional rinsing stage after disinfection to help remove residual disinfectant.
Automating these stages reduces the number of manual actions required during routine processing and helps maintain a consistent sequence of operations.
Water Filtration and UV Treatment
The water circulation system incorporates two water filters and an integrated ultraviolet lamp.
Water filtration and UV treatment form part of the automated reprocessing system. An additional air filter is also included in ScopeJET A2.
These components complement the washing, disinfection and rinsing stages performed within the programmed processing cycle.
Automatic Dosing and Cycle Documentation
ScopeJET A2 automates the supply of disinfectant, detergent and alcohol according to the selected processing program.
The reprocessor also features a built-in printer, which provides a printed record after each completed processing cycle.
Documented cycles support routine recordkeeping in endoscopy departments and provide personnel with information about completed reprocessing procedures.
Key Advantages of the New ScopeJET A2
- Two Endoscopes per Cycle: Simultaneous washing and high-level disinfection of two flexible endoscopes instead of one.
- 14-Liter Processing Bath: Increased chamber capacity for the new dual-endoscope configuration.
- Eight Configurable Profiles: Individually adjustable processing programs for different endoscope reprocessing requirements.
- Automatic Leak-Tightness Testing: Integrated endoscope integrity testing during the processing cycle.
- Double Rinsing: An additional rinsing stage to help remove disinfectant residues.
- Automatic Fluid Dosing: Program-controlled supply of disinfectant, detergent and alcohol.
- Integrated Cycle Documentation: Built-in printer for recording completed washing and disinfection procedures.
ScopeJET A2 vs Previous SterixX Reprocessor
The following comparison highlights the main technical differences between the new ScopeJET A2 and the previous single-endoscope reprocessor.
| Specification | New ScopeJET A2 | Previous SterixX / ScopeJET A1U |
|---|---|---|
| Endoscope Capacity | 2 flexible endoscopes | 1 flexible endoscope |
| Processing Bath | 14 L | 7 L |
| Disinfectant Tank | 15 L | 8 L |
| Detergent Tank | 1 L | 1 L |
| Alcohol Tank | 1 L | 1 L |
| Configurable Processing Profiles | Up to 8 | Not specified |
| Leak-Tightness Testing | Automatic during processing | Continuous monitoring |
| Double Rinsing | Yes | Yes |
| Water Filtration | 2 filters | 2 filters |
| UV Treatment | Integrated | Integrated |
| Automatic Fluid Supply | Disinfectant, detergent, alcohol | Automatic disinfectant intake |
| Built-in Printer | Yes | Yes |
| Power Consumption | 400 W | 400 W |
| Weight | 65 kg | 60 kg |
Comparison based on the published Brightfield product specifications. “Not specified” means the parameter is not confirmed in the available description of the previous model.
Expanding Brightfield’s Endoscope Reprocessing Range in 2026
The introduction of ScopeJET A2 represents an important expansion of Brightfield’s automated endoscope reprocessing equipment range.
While the previous single-endoscope system remains relevant for facilities with lower reprocessing volumes, the new ScopeJET A2 provides an additional configuration for departments that need to process two flexible endoscopes during the same cycle.
Its combination of increased processing capacity, computer-controlled programs, automatic leak-tightness testing, filtration, rinsing and cycle documentation is intended to support the daily requirements of modern endoscopy departments.
Discover the New ScopeJET A2 — 2026 Product Release
The new ScopeJET A2 expands the Brightfield reprocessing equipment range with a dual-endoscope configuration designed for automated washing and high-level disinfection.
Explore the Brightfield ScopeJET A2 Automatic Endoscope Reprocessor and review its technical specifications.
Interested in the new ScopeJET A2? Our team can provide additional information about technical specifications, available configurations and ordering options.